OPERATING GUIDE for your
GEM-DXRP2 KEYPAD
AC ON
READY
OI323 11/06
© NAPCO 2006
TABLE OF CONTENTS
TO SILENCE AN ALARM, ENTER YOUR
TABLE OF CONTENTS
CODE, AND PRESS J.
Section
Page
FOR SERVICE, CALL: _____________________
CENTRAL STATION: _____________________
EXIT DELAY: ___________________________
ENTRY DELAY: _________________________
KEYPAD CONTROLS & INDICATORS............................................4
SETTING THE ALARM (ARMING) WHEN LEAVING.......................6
PROTECTING YOURSELF WHILE ON THE PREMISES ................9
TURNING OFF THE ALARM (DISARMING) WHEN RETURNING...11
FIRE PROTECTION.........................................................................13
KEYPAD FUNCTIONS.....................................................................17
CENTRAL-STATION MONITORING................................................22
ADVANCED FEATURES .................................................................23
PROGRAMMING .............................................................................25
KEYPAD MESSAGES......................................................................28
GLOSSARY .....................................................................................32
SYSTEM TROUBLE ERROR CODES .............................................35
FIRE ALARM SOUND*:
_____________________________________
BURGLAR ALARM SOUND*:
_____________________________________
KEYPAD FIRE ENABLED?
KEYPAD PANIC ENABLED?
KEYPAD AUX. ENABLED?
YES NO
YES NO
YES NO
*FIRE HAS PRIORITY OVER BURGLARY.
3
KEYPAD CONTROLS & INDICATORS
AC ON
READY
4
KEYPAD CONTROLS & INDICATORS
Window. Displays system status
messages, zone descriptions, etc.
INSTANT Button. (1) Cancels
entry delay on Exit/Entry Zones,
causing an instant alarm upon
violation. (2) Scrolls window
display backward (PRIOR). (3)
Answers “NO” to questions in the
window display.
BYPASS Button. (1) Deactivates
selected zones from the system.
(2) Unbypasses a bypassed zone
(GEM-P3200/9600 panels only).
STATUS Light. Lights (green) to
indicate that the system is ready
for arming. If a zone is not
secured the light will be off and
the zone will display in the
window. If a zone has been
bypassed, the STATUS light will
blink while armed.
RESET Button. (1) Resets
various system troubles, displays,
etc. (See text.) (2) Resets
residential smoke detectors.
AREA Button (*). Selects other
areas and is used with
emergency buttons.
Numerical Keys (1-9, 0). Used to
enter codes, zone numbers, etc.
ARMED Light. Lights (red) to
indicate that the system is armed.
If an alarm has occurred, the
ARMED LED will be flashing.
Emergency Buttons. Used with
the G button to signal an
emergency, as follows:
ON/OFF Button. Entry key.
Causes the entered code or
selected function to be executed.
Press the 7 and the
G
G
buttons for Fire Emergency.
FUNCTION Button. Selects
available system functions as
displayed in the window. The
selected function is executed by
pressing the Jto button.
INTERIOR Button. (1) Bypasses
all Interior Zones simultaneously
to allow free movement within the
premises. (2) Scrolls the window
display forward (NEXT). (3)
Answers “YES” to questions in
the window display.
Press the 8 and the
buttons for Auxiliary Emergency.
Press the and the
buttons for Police Emergency.
9
G
5
SETTING THE ALARM (ARMING) WHEN LEAVING
Arming the System
READY
Note: The keypad will autoscroll messages that are longer than one line.
AC O N
1 Check the keypad. The green STATUS light must be on in order to arm. If the
green light is off, “FAULT” will display in the window followed by the number of
each faulted zone. Note each problem zone and secure it by closing a window,
door, etc. When all zones are secure, the green STATUS light will turn on and the
FAULT/
ZONE 02
AC O N
window will display “READY”.
Bypass faulted zones. If you cannot locate or repair the problem yourself, call
READY
for assistance. If you cannot get immediate help, bypass the problem zone(s)
B Y P A S S E D
A C O N
from the system by pressing B, then the zone number (or vice versa). Note:
Bypassed zones areunprotected. Ifarmed with zones bypassed, be sure to have
the system checked as soon as possible.
EXIT/
XX SEC
2 Arm the system.Enteryourcode and press J. The green STATUS light will go
AC O N
off, the red ARMED light will turn on and the window will alternately display “EXIT"
and "XX SEC" (where “XX” represents the exit time remaining, in 10-second
steps). Note: If you enter an invalid code, the keypad will display “Wrong Code”.
3 Leave the premises. Leave through the exit door before exit time expires.
6
SETTING THE ALARM (ARMING) WHEN LEAVING
Priority Arming. If you attempt to arm with a faulted Priority Zone, a 3-second tone will
CAN'T/
ArmZnF
sound at the keypad, and "CAN'T/ArmZnF" will display in the window, indicating that
AC O N
the trouble(s) must be corrected before the panel can be armed. A zone selected as
Priority Zone with Bypass (check your Alarm Plan) may be bypassed if in trouble. If
the problem cannot be corrected immediately, press C, then arm the panel. A 3
second beep will sound at the panel to indicate arming with a Priority Zone in trouble.
Be sure to have the trouble repaired as soon as possible.
Silence Alarm. If you enter your code while the alarm is sounding the message
CAN'T/
ArmSil
"CAN'T/ArmSil" will be displayed. The system will silence the alarm and will be ready
to be armed again.
AC O N
Alarm Sounding. If you are attempting to arm with Easy Arm (Optional) and the alarm
CAN'T/
is sounding, "CAN'T ArmSnd" will be displayed. The alarm will not silence. Only a
AC O N
ArmSnd
valid User Code will silence the alarm.
System Trouble. If you enter your User Code with a system trouble present, the mes-
T R O U B L E
AC O N
CAN'T/
ArmRst
sage "CAN'T ArmRst" will be displayed. To arm, press C and the system trou-
bles should disappear.
7
SETTING THE ALARM (ARMING) WHEN LEAVING
If you attempt to arm with a “TROUBLE” display (alternating with a system trouble error code), a 3-
T R O U B L E
second tone will sound at the keypad. (See SYSTEM TROUBLE ERROR CODES for descriptions
of codes). The window will display “CAN'T ArmRst”. If you cannot correct the problem
immediately, pressing C will enable you to arm in this condition. Be sure to call for service as
TRBL
EXX-XX
AC O N
T R O U B L E
AC O N
soon as possible.
CAN'T/
ArmRst
Area Arming (Optional)
Some systems may be divided, or partitioned, into smaller independent subsystems, which are
referred to as Areas. In a system that has been partitioned into multiple areas, one or more area
may be armed while others remain disarmed. In a multi-area system, the area number will be
indicated by the right-most digit.
READY1
AC O N
Manager's Mode The Manager's Mode, if enabled, provides quick access to other areas without
the system status display. (This is NOT a high-security feature).
To arm any area:
1. Press the numerical key representing the area number.
2. Press G followed by J. In effect, you will now "be" in that area.
3. Enter your User Code followed by J to arm or disarm the area. Note: Your code must be
valid in that area.
4. Press G followed by J to return to the home area.
Global Arming (Optional) (Not available with GEM-P1632/816 panels)
CAN'T/ARM/
AREA#
A C O N
To arm all areas simultaneously, press 9, G and enter your code followed by J.
To disarm all areas simultaneously, press 0, G and enter your code followed by J.
If any zone is not secured, the keypad will alternately display "CAN'T ARM / AREA #", where
"#" identifies the number of the area(s) in trouble. All problem zones in the respective area(s)
must be secured or bypassed before the area can be armed. Note: If a system trouble is
indicated, the system cannot be armed using this method.
8
PROTECTING YOURSELF WHILE ON THE PREMISES
Bypassing Interior Zones
Interior Zones, when bypassed, allow free movement within the premises while the protection of
B Y P A S S E D I N T E R I O R
AC O N
READY
armed perimeter zones is maintained. If E is pressed, all interior Zones will be bypassed upon
arming.
(OPTIONAL) Some control panels (such as the GEM-P9600) have provisions for TWO groups of Interior Zones. If two groups of zones were
programmed, proceed as follows:
INT1+2
READY
ARMED
1. Select the interior group by repeatedly pressing E. The window will display "INT1". "INT2",
or "INT1+2".
AC O N
2. When the desired interior group is displayed, press D to select it. "BYPASSED" and
B Y P A S S E D I N T E R I O R
AC O N
"INTERIOR" will display to indicate interior zones bypassed.
3. Enter your code, then press D. The red ARMED light will turn on and the green STATUS light
B Y P A S S E D I N T E R I O R
AC O N
will blink, indicating zones bypassed. After the exit time has elapsed, the window will display
"ARMED" and "BYPASSED INTERIOR" will be displayed.
Automatic Interior Bypass (Optional - Automatic Interior Bypass programmed? YES NO)
Your system may have been programmed for Automatic Interior Bypass, which allows it to recognize
that you have armed the system and remained in the house, prompting it to automatically bypass
any Interior Zones. In this case, the keypad display will normally show the icon "BYPASSED", ex-
B Y P A S S E D
AC O N
READY
cept when the system is armed, and the Exit Entry door is opened. At this time those Interior Zones will unbypass, providing complete interior
protection.
Easy Exit (Optional - Available on systems containing Interior Zones).
While the system is armed in the Automatic Interior Bypass state, the Easy Exit option is available. To exit the premises while the system is
armed, press D and the Exit Delay countdown will begin. You can now exit the premises through the Exit/Entry door and the system will return
to the armed state when the countdown expires.
9
PROTECTING YOURSELF WHILE ON THE PREMISES
Instant Protection
When retiring for the evening, after all family members are home, you can cancel the
I N S T A N T O N
ARMED
AC O N
entry delay on the Entry Zone(s). Then, when armed, opening the entry door will cause
an immediate alarm. (When arming, exit delay will remain in effect).
1. To cancel the entry delay while on the premises, merely press F. (The F button may be pressed either before or
after arming).
2. When armed, the window will display "ARMED", and "INSTANT ON" and the red ARMED light will flicker rapidly to indicate
instant protection.
Emergency Buttons (Only available if programmed)
The Blue Emergency Buttons (7,8& 9), if programmed, are always active,
whether the system is armed or disarmed. The emergency signal will only be transmitted
when an Emergency Button and G are pressed at the same time.
• Fire Emergency Simultaneously press 7 and G to alert the central station of a fire
emergency. *(Fire Emergency programmed? YES NO)
• Auxiliary Emergency Simultaneously press 8 and G to alert the central station of
an Auxiliary emergency. *(Auxiliary Emergency programmed? YES NO)
• Police Emergency Simultaneously press 9 and G to alert the central station of a
police emergency. *(Police Emergency programmed? YES NO)
10
TURNING OFF THE ALARM (DISARMING) WHEN RETURNING
Disarming the System
DISARM/
AC O N
XXXSEC
1 Upon entry, the keypad sounder will pulse as a reminder to disarm the panel. The red
ARMED light will be on and the window will alternately display "DISARM" and "XXXSEC",
where "XXX" represents the entry time remaining in 10-second steps. During the final 10
seconds, the sounder will pulse (rapidly) a warning signal.
Wrong/
Code
AC O N
2 Enter your User Code and press D. The sounder will silence and the red ARMED light
will go out, indicating that the system has been disarmed.
• If you enter an invalid code, the keypad display "Wrong Code" Re-enter your code
immediately.
Alarm Indication / Silencing an Alarm
ALARM/
ZONE02
AC O N
If the red ARMED light is flashing and “ALARM” is displayed, an alarm occurred while you
were out. Proceed with caution! If you suspect that an intruder may still be on the premises,
leave immediately and call authorities from a neighbor's phone.
To silence an audible alarm:
1 Enter your code and press J. After the system is disarmed, the window will continue to
display “ALARM” followed by the zone(s) violated.
2 To reset the display, note the zones violated, then press C.
11
TURNING OFF THE ALARM (DISARMING) WHEN RETURNING
Ambush (Optional) Your Ambush Code Type is: TYPE 1 (Prefix) TYPE 2 (Unique) My Ambush Code is ___________________
If an intruder forces you to disarm your system, enter your Ambush Code and press J. There are two types of Ambush Codes: (1) A
2-digit code (prefix) entered just prior to your normal User Code and (2) A separate and unique User Code.
Example Type 1 (Prefix): If your User Code is 1234 and your Ambush Code is 99, press 991234J.
Example Type 2 (Unique): If your User Code is 1234 and your Ambush Code is 8899, press 8899J
Using your Ambush Code will send a silent alarm to the central station. The red ARMED light will go out and the window will display
“SYSTEM READY” as if the system were normally disarmed. There will be no indication that a silent alarm has been sent.
Day Zone (Day Zone(s) programmed? YES NO)
A Day Zone is used to monitor a secured exit door, window foil, etc. A problem on this type of burglary zone will cause a “DAY ZN” dis-
play followed by “ZONEXX” (xx represents the zone number) and a pulsing keypad sounder while disarmed. To silence the sounder,
press C (or arm and disarm, if so programmed). Correct the problem to reset the Day Zone.
24-Hour Zone (24-Hour Zone(s) programmed? YES NO)
This zone is always armed, even if the system is disarmed. If there is no audible output (bell, siren, etc.) programmed for this zone, it
will behave as a regular Burglary Zone, however an alarm will be reported to the central station and recorded in the Alarm Event Log. If
an audible output is programmed, a 24-Hour Zone will behave as an armed Burglary Zone. If the system is subsequently armed with a
24-Hour Zone in trouble, the keypad sounder will come on momentarily to indicate that there is a problem.
12
FIRE PROTECTION
(Applicable only where local ordinance permits use of this alarm control panel for fire protection.)
Fire-Zone Alarm
r e s e t F I R E A L A R M
FIRE/
ZONEXX
If a fire is detected, “reset FIRE ALARM” will be displayed and the keypad sounder will
AC O N
pulse.
1. If a fire is in progress, evacuate the premises immediately! If necessary, call the
Fire Department from an outside phone.
2. Press the C button to silence the keypad sounder.
3. If there is no evidence of a fire, enter your User Code and press J to turn off the
alarm.
4. Check smoke detector(s). If a smoke detector tripped, its red alarm indicator light
will be on.
After the alarm condition is corrected (thermostat cooled down; smoke cleared from
detector; etc.), pressing C again will reset the keypad within about 10 seconds.
Fire-Zone Trouble
T R O U B L E
TRBL/
E41-XX
1. If a problem in the fire-circuit is detected, “TROUBLE” (fire trouble) will display and
AC O N
the sounder will pulse to signal a malfunction.
2. Press C to silence the sounder. Call for service immediately!
13
FIRE PROTECTION
closed.
3. Test the door. If it is hot, use your
alternate route through the window. If
the door is cool, brace your shoulder
against it and open it cautiously. Be
ready to slam the door if smoke or heat
rushes in. Crawl through smoke,
holding your breath. Close the doors
again on leaving to help prevent the
fire from spreading.
Preparing a Fire Escape Plan
2. One person sounds the alarm.
3. Each person tests his door.
Even with the most advanced fire
alarm system, adequate protection
requires an escape plan.
4. Pretend the door is hot and use the
alternate escape exit.
5. Everyone meets outdoors at the
assigned spot.
To prepare your plan, draw floor plans
of your building. (Space is provided on
the next page). Show two exits - a front or
back door and a window from each room.
(Make sure the window works. You may
need a special fire-escape ladder if the
window is high up). Write down your
outside meeting place.
Important! - Read Carefully
Discuss these escape procedures with all
those who use the building:
4. Go to your specific outdoor meeting
place so you can see that everyone is
safe.
5. Assign someone to make sure nobody
returns to the burning building.
6. Call the Fire Department from a
neighbor's telephone.
1. In a residence, sleep with the bedroom
door closed. A closed door will hold
back deadly smoke while you escape.
2. When the fire alarm signals, escape
quickly. Do not stop to pack.
Family Rehearsal.
Rehearse each of the following activities:
1. Everyone in his room with the doors
Would You Like More Safety Information?
For more information on home fire detection, burn safety, and home fire safety,
write to the National Fire Protection Association, Public Affairs Dept. 05A,
Batterymarch Plaza, Quincy, MA 02269.
14
FIRE PROTECTION
Floorplan
Draw a plan of your premises in the space provided below.
Floorplan
15
FIRE PROTECTION
LIMITATIONS OF FIRE ALARM WARNING SYSTEM
reasons: (a) they may not sense fires that
start where smoke cannot reach them, such
as in chimneys, walls, roofs, behind closed
doors, etc.; (b) they may not sense a fire on a
different level of the residence or building; (c)
they have sensing limitations; no smoke
detector can sense every kind of fire every
time.
radio, air conditioner, or other appliance, or
by passing traffic, etc. Alarm warning
devices, however loud, may fail to warn the
hearing impaired.
Although a fire alarm system may be of a
reliable and state-of- the-art design, neither it
nor its peripheral detection devices can offer
guaranteed protection against fire. Any such
equipment may fail to warn for a variety of
reasons:
Alarm products, as all electrical devices,
are subject to component failure. Even
though the equipment is designed for many
years of trouble-free performance, electronic
components could fail at any time.
Control panels, communicators, dialers,
smoke detectors, and many other sensing
devices will not work without power. Battery-
operated devices will not work without
batteries, with dead batteries, or with
improperly-installed batteries. Devices
powered solely by AC will not work if their
power source is cut off for any reason.
Thermostatic heat detectors do not
always detect fires because the fire may be a
slow smoldering low-heat type (producing
smoke); because they may not be near the
fire; or because the heat of the fire may
bypass them. These detectors will not detect
oxygen levels, smoke, toxic gases, or flames.
Therefore, they may only be used as part of
a comprehensive fire-detection system in
conjunction with other devices. Under no
circumstances should thermostatic heat
detectors be relied upon as the sole measure
to ensure fire safety.
Above are some of the reasons that fire
alarm equipment could fail. The most
common cause of an alarm system not
functioning when a fire occurs is inadequate
testing and maintenance. The system should
be tested at least weekly to ensure that all
the equipment is working properly.
Fires often cause a failure of electrical
power. If the system does not contain a
working battery backup power supply, and if
the electrical circuit feeding the devices is cut
or is not providing power for any reason, the
system will not detect heat or smoke or
provide any warning of a possible fire.
While an alarm system may make one
eligible for lower insurance rates, it is not a
substitute for insurance. Homeowners,
property owners, and renters are therefore
urged to maintain adequate insurance
coverage of life and property.
Alarm warning devices such as sirens,
bells, or horns may not alert someone behind
a closed or partially-opened door. Warning
devices located on one level are less likely to
alert those on a different level. Even those
who are awake may not hear the warning if
the alarm is obscured by noise from a stereo,
Telephone lines needed to transmit
alarm signals to a central monitoring station
may be out of service.
Smoke detectors, though highly effective
in reducing fire deaths, may not activate or
provide early-enough warning for a variety of
16
KEYPAD FUNCTIONS
The keypad can provide access to a wide assortment of utility functions. The functions are displayed in a prompting
“YES/NO” format. While the messages are shown here in their entirety, actual displays will scroll automatically in two
screens. Wait for the entire message to display. To skip a function, answer NO (press F); to select and execute a
function, answer YES (press E) or D. The complete function list is provided here in its normal displayed sequence.
However, since not all functions are designed for all systems (or intended for all users), only functions that are applicable
and active are displayed. (For example, if no zones are bypassed, "Disp Bypass" (Display Zones Bypassed) will not ap-
pear). In addition, functions that are intended for use by the installer or servicer will not be displayed. (Note: Functions
may be manually scrolled forward or backward using A and B, respectively).
Display Zone Status? (OPTIONAL) Identifies zones that are not secured. Press the
NEXT and PRIOR Buttons (as displayed on-screen) to scroll faulted zones.
DspZn/ Status/
Yes/ No
A C O N
Display Zones Bypassed? Displays manually bypassed zones. Press NEXT(E)
and PRIOR (F) to scroll bypassed zones.
B Y P A S S E D
A C O N
Dsp/ Bypass/
Yes/ No
Display Zone Directory? Displays each zone by number. Press NEXT(E) and
PRIOR (F) to scroll zone directory.
DspZn/ Dir/
Yes/ No
A C O N
A C O N
Bell / Test/
Yes/ No
Activate Bell Test? Activates the alarm (while disarmed) for about 2 seconds. If the
alarm does not sound, call for service.
17
KEYPAD FUNCTIONS
Display Telephone List? (OPTIONAL) (For GEM-P9600/3200 panels only). (Phone Numbers
Programmed? YES NO). The panel can dial any of four programmed telephone numbers.
DspTel / List/
Yes/ No
A C O N
Select Telephone #1-4 using the NEXT and PRIOR buttons. Press D, then pick up the phone
to automatically dial the displayed number.
Display System Troubles? (For GEM-P9600/3200 panels only). Displays a 2-digit error code
(EXX-NN) representing the problem (XX) detected in the system, followed by 2 digits (NN) identi-
fying the problem zone, keypad, module, etc. (See SYSTEM TROUBLE ERROR CODES for a
description of these codes). Use NEXT(E) and PRIOR (F) to scroll system troubles.
DspSys/ Tr bl/
Yes/ No
A C O N
Display Fire Alarms? (For GEM-P9600/3200 panels only). Displays alarms that have occurred on
the Fire Zone(s). Press the NEXT and PRIOR Buttons to scroll zones.
r e s e t F I R E A L A R M
A C O N
DspFi r/ Alarm/
Yes/ No
Display Fire Troubles? (For GEM-P9600/3200 panels only). Displays trouble conditions that
T R O U B L E
A C O N
DspFi r/ Trbl/
Yes/ No
have been detected on the Fire Zone(s). Use NEXT(E) and PRIOR (F) to scroll fire
troubles.
Activate Overview? (OPTIONAL) (For GEM-P9600/3200 panels only). (Overview programmed
Tur nOn/ O vi ew
Yes/ No
for user? YES NO). In a partitioned system, this mode displays the status of Areas 1 and
2 simultaneously. (The “READY1” display will be replace by the “OV(--)” display shown at left).
For each area: “R” = Area Ready; “z” = Zone Fault; “A” = Area Armed; “B” Burglary Zone in
Alarm; “F” Fire Zone in Alarm; “T” = Fire Trouble; "c” = Check Trouble; Area in Function-Display
Mode.
A C O N
A C O N
OV(RZ)
In this mode, all areas (except the area that you are in) may be armed by pressing 9. G,
then entering a valid User Code. (The User Code must be valid in all areas). Similarly, all areas
may be disarmed by pressing 0, G, then entering a valid User Code. To revert to nor-
mal keypad operation, enter a valid code, press A repeatedly until "TrnOff O View" appears,
then press the YES (E) button.
18
KEYPAD FUNCTIONS
Activate Chime? "MONITOR ON" will be displayed and the Chime Mode will sound a tone
at the keypad when the programmed zone is opened while disarmed. To deactivate the
Chime Mode, execute the "TurnOff Chime" function.
Tur nOn/ Chi me
Yes/ No
A C O N
Note: The Chime Mode is disabled while armed.
Activate Watch Mode? (Watch Mode programmed? YES NO). This optional feature
simultaneously turns on all zones designated as Day Zones. When activated, “MONITOR
ON” will display at the keypad. To deactivate the Watch Mode, arm, then disarm. All Day
Zones will revert to regular Burglary Zones. Note: The Watch Mode is disabled while
armed.
Tur nOn/Watch
Yes/ No
A C O N
T R O U B L E
A C O N
Reset System Trouble? System troubles display and sound at the keypad. Correcting
the trouble will clear most indications, however the following error codes will require manual
reset: E11; E13; E19; E20 and E22. (See SYSTEM TROUBLE ERROR CODES for a de-
scription of error codes).
Reset/ SysTbl/
Yes/ No
Start Exit Time? (OPTIONAL) (Start Exit Time programmed? YES NO). In Com-
mercial Burglary systems, exit delay may have been programmed to start after a central-
station “ringback” (verification) signal has been received. If the ringback tone has not been
received within about 30 seconds after arming, a communication problem may exist. Use
the “START EXIT TIME” Function to start exit delay manually, then exit the premises imme-
diately. Be sure to have your alarm specialist check communications with the central station
as soon as possible.
Star t/ Exi tTm/
Yes/ No
A C O N
Activate Telephone Test? (OPTIONAL) (Telephone Test programmed? YES NO).
Sends a communicator test to the central station. A communication failure will be indicated
at the keypad by an “E03-00 COMMFL” display. Repeat the test to attempt to correct a com-
munication failure, as any successful communication will clear this display.
TurnOn/Tel Tst/
Yes/ No
A C O N
19
KEYPAD FUNCTIONS
Delay Arming 1-4 hours. (Not for UL-listed systems). Your system may be set to
arm automatically after a delay period of 1 to 4 hours, 15 minutes, as follows:
Del ay/ Ar m 1-4/
/ No
A C O N
For a 1-hour, 15-minute delay, press 1, then D.
For a 2-hour, 15-minute delay, press 2, then D.
For a 3-hour, 15-minute delay, press 3, then D.
For a 4-hour, 15-minute delay, press 4, then D.
Fifteen minutes prior to arming, the siren will sound a 2 second warning and the key-
pad will begin a 15 minute countdown with the sounder pulsing. During this time, arm-
ing may be delayed an additional 1 to 4 hours (as above), or autoarming may be can-
celled by arming and disarming the panel.
TurnOn/Pr og/
Yes/ No
Activate Program? (Program Mode programmed for user? YES NO). Activates
the Program Mode from Keypad No. 1 only. Note: This feature is disabled while
armed.
A C O N
Tur nOn/ DwnLd
Yes/ No
Activate Download? Activates the Manual Download Mode from Keypad num-
ber 1 (For installer or servicer's use only). Note: This feature is disabled while
armed.
A C O N
20
KEYPAD FUNCTIONS
Display RF Transmitter Status? (OPTIONAL) (For systems that include wireless trans-
mitters). Press YES to check the status and condition of all transmitters. First the number
of wireless points (WL PNT) will display. Use NEXT and PRIOR Buttons to scroll forward or
back. For each transmitter, the following information will be shown:
RF Xmt/Status/
Yes/ No
A C O N
123456/
Z01S10
•
•
Transmitter ID Code number (6 numbers and/or letters).
Zone ("z”) to which transmitter is mapped and signal strength "s" (01—10, 10 being the
strongest) of its last transmission.
A C O N
123456/
Z01BAT
A display of "Z01BAT" (battery) indicates that the transmitter on Zone 1 has a battery that is
weak and requires replacement.
A C O N
A C O N
A C O N
A display of "Z01TAM" (tamper condition) indicates that the case of the transmitter on Zone
1 is open.
123456/
Z01TAM
A display of "Z01SUP" (supervisory failure) indicates that a test signal from the transmitter
on Zone 1 has not been received.
123456/
Z01SUP
Rel ay/ Ctrl/
Yes/ No
Relay Control? (OPTIONAL) Turns on (or off) one or more programmed Relay Groups.
A C O N
A C O N
Press D to turn the displayed group on or off; press NEXT to proceed to the next group, or
PRIOR to scroll back to the previous group. Press C when done. (Note: Relay group
RG-OFF/
(DESCRI PTI ON)
description must be entered).
21
CENTRAL STATION MONITORING
Your alarm specialist may have
arming (Closing Report), the central
Opening and/or Closing Reporting.
Your system can notify the central
station every time it is disarmed or
armed. Any or all of up to 96
programmed your system to be
monitored by a central station. The built-
in digital communicator can transmit
emergency signals and status reports to
the central station 24 hours a day.
station will acknowledge arming.
This will signal at the keypad as a
“ringback” beep. Note: If the
ringback signal is not heard, call for
service.
different users can each be
identified. If your system reports on
Communicator Features
Abort Delay. Ask your installer which
of your zones have Abort Delay, a
delay that enables you to reset the
system before it communicates to
the central station. Your system
has a SIA CP-01 required Abort
Delay of 30 seconds. It may be re-
moved or increased up to 45 sec-
onds (at your option) by consulting
with your installer.
Regular Burglary (Non-24-Hour) Zone
reports are aborted by disarming
within the delay period. 24-Hour
Zones and zones programmed to
report restores must be restored
first, then the panel armed and
disarmed, all within the delay
period.
22
ADVANCED FEATURES
Security Bypass/Unbypass
FAULT/
ZONE02
(Security Bypass programmed? YES NO). In high-security applications, zones may be
bypassed (or unbypassed) only if a valid code is entered first, as follows:
1. Enter a User Code valid for bypass, then press B. "BYPASS" will display.
AC O N
AC O N
2. Press B then the zone number (or vice versa) to deactivate that zone.
Similarly, a bypassed zone may be unbypassed using the same procedure. (This feature
available for GEM-P3200/9600 panels only).
BYPASS
WAIT
Start Exit Time After Ringback
(For Commercial Burglary Systems only) (Optional - Start Exit Time programmed?
A C O N
YES NO).
If your system reports to a central station, your panel may have been programmed to start exit delay after the central-station
ringback (verification) signal. Then, after arming, your system will communicate to the central station. After the central station
acknowledges receipt (ringback), exit delay will start. If ringback is not heard within about 30 seconds, a communication
problem may exist; call for service. The Start Exit Time function may then be used to manually start the exit delay, however
reporting capability may be sacrificed. (If your system does not report or the ringback feature was not programmed, exit delay
will start as soon as your code is entered. Also note that if an exception window is programmed, and the closing is within that
window, no ringback is provided. Ask your alarm professional if this feature is enabled).
Exit-Delay Restart
(Exit-Delay Restart programmed? YES NO).
On arming, the programmed exit delay will start. After the exit door has been opened and then closed, exit delay will change
to 60 seconds. Thus, a long exit delay may be programmed, which will immediately be reduced to 60 seconds upon exiting.
If re-entry occurs during that 60 seconds, exit delay will restart once again (and only once again) at 60 seconds. If so
programmed, re-entry within 60 seconds after exit delay has expired will cause the alarm to sound a 2-second warning (in
addition to the entry sounder) to remind the user to disarm.
23
NOTES
24
PROGRAMMING (OPTIONAL)
off and burglar and fire alarm func-
tions are disabled.
not allowed; therefore a duplicate Code en-
tered in the LCD Window will erase when
Introduction
The Program Mode (optional) is used to
customize User Codes. Access to the
Program Mode requires a special User
Code, therefore not all users may have
the ability to program.
D is pressed.
5. If the keypad detects no activity in the
Program Mode for more than 4 min-
utes, a tone will sound; to silence the
tone, press the blue G button.
The User Program Mode is accessed from
the Function Mode as follows:
1. Enter your code, then press A to
6. The programmed code or description
will not be permanently stored until
enter Function Mode.
Notes:
you press D.
2. Answer NO (press F) until
1. If the system contains more than one
keypad, only the keypad designated
“No. 1” may be used for programming
(if in doubt which is No. 1, ask your
installer).
"TurnOn Prog Yes/No" is displayed,
then press the YES button (E).
"User01" will display.
7. To exit the Program Mode, press
C.
Note: If you pass "TurnOn Prog", press
B to scroll back.
Programming User Codes
2. Operation of the keypad buttons in
the Program Mode is different from
that for normal operation. Refer to the
accompanying diagram for keypad
functions in the Program Mode.
Do not attempt to program a code contain-
ing any blank spaces between digits. In
selecting your codes, do not program re-
petitive numbers (1111), consecutive
numbers (1234), your birth date, address,
or other obvious combinations. Choose a
code of up to six digits (a minimum of four
is recommended, and required in UL in-
stallations). NOTE: Duplicate Codes are
3. Using the number buttons, enter a
User Number as a two-digit number
(enter 1-9 as "01" - "09").
4. Press A. The cursor will advance
3. If the selected function requires more
than one screen, scroll the display
using A.
to the User Code screen and read the
existing code, if any.
(continued)
4. While in the Program Mode, the
ARMED and STATUS lights remain
25
PROGRAMMING (OPTIONAL)
5. Enter the new User Code using the
number buttons. If an old code is
displayed, simply program over it.
To Program User Codes
1. Using Number buttons,
enter User Number
To erase the digit at the cursor,
press G, then 0.
User
2. Press A
Note: Pressing A again will dis-
play non-programmable "OPTion" and
"ACCess" screens. Do not attempt to
program these screens as the entries
will not be saved.
3. Using number buttons,
enter User Code of up to
6 digits.
4. Press D to save.
6. Press D to save the code in mem-
ory. Repeat steps 3-6 for each user.
5. Press C to Exit Pro-
Note: Press G, 0 to clear
gram Mode.
Note: Duplicate Codes are not allowed;
character at cursor.
therefore a duplicate Code entered in
the LCD Window will erase when D
Programming User Codes
is pressed.
Note: To void a code, blank out each
digit by pressing G 0, then
press the Save (D) button.
26
PROGRAMMING (OPTIONAL)
Programming Example:
cate Code entered in the LCD Window will erase when D is
Program the User 3 Code to “3784”:
1. Select the Program Mode as follows:
(a) Enter your User Code, followed by A.
pressed.
• If the system contains more than one keypad, only the
keypad designated “No. 1” may be used for programming
(if in doubt which is No. 1, ask your installer).
(b) Answer NO (press F ) repeatedly until “TurnOn
Prog Yes/No” is displayed, then press YES (E).
The display will briefly read:
"User01" (User 1's Code).
• While in Program Mode, the ARMED and STATUS lights
remain off and burglar and fire alarm functions are
disabled.
“UPXXXX” then
2. Press 03 for User No. 3.
• In selecting your codes, do not program repetitive
numbers (1111), consecutive numbers (1234), your birth
date, address, or other obvious combinations. Choose a
code of up to six digits (a minimum of four is
recommended, and required in UL installations). If the
keypad detects no Program Mode activity for more than 4
minutes, a tone will sound. Press C to silence.
3. Press A to advance to the User Code screen.
4. Press 3784 to program the code.
If any other digits are left over from a previous User-3
Code, delete each by pressing G 0.
Note: Do not attempt to program the "OPTion" or
"ACCess" screens (if they display) as they will not be
saved.
5. Press J to save the code.
6. Press C to exit the Program Mode.
Notes:
• Note: Duplicate Codes are not allowed; therefore a dupli-
27
KEYPAD MESSAGES
The keypad can display the following functional messages. Many are two-line messages; hold down G to display the second
line. (In this booklet, both are shown simultaneously for convenience). Other diagnostic messages are available for the installer or
servicer. Should any unfamiliar messages appear, call your dealer for service.
All zones operating; system can be armed. If displayed, a number following the “READY”
READY
display denotes the area number. A "MONITOR ON" display indicates that Chime or
AC O N
Watch Mode is on. Note: If Watch Mode is programmed, “MONITOR ON” will not dis-
play for Chime Mode.
Panel reporting to central station on arming. If necessary, wait for ringback signal before
WAIT
exiting.
AC O N
Exit delay in progress. XX denotes exit time remaining. If displayed, BYPASSED indicates
EXITXX
arming with zones bypassed; INSTANT ON indicates arming with Instant protection.
AC O N
Entry delay in progress. XXX shows entry time remaining.
DISARM
AC O N
XXXSEC
Panel armed. If displayed, a number following the ARMED display denotes the area num-
ARMED1
ber.
AC O N
Zone(s) not secured (doors or windows may be open). Faulted zone(s) will scroll.
FAULT
AC O N
28
KEYPAD MESSAGES
Arming attempted with zone in trouble. Faulted zones will scroll. Correct trouble to
arm.
CAN'T/
ArmZnf
AC O N
Arming attempted while the alarm is sounding. A valid user code will silence the
sound and clear this message.
CAN'T/
ArmSil
AC O N
Attempted to arm with Easy Arm and the alarm is sounding. The alarm wit not si-
lence without a valid user code.
CAN'T/
ArmSnd
AC O N
Arming attempted with a system trouble present. To arm, press C and the sys-
tem troubles will disappear.
CAN'T/
ArmRst
AC O N
The alarm signal has been cancelled during the Abort Delay (before an alarm signal
report was sent to the central station). If cancelled after the alarm signal report was
sent, this message appears when the system receives an acknowledgment from the
central station of the cancellation of the alarm signal.
T R O U B L E
AC O N
CANCEL
29
KEYPAD MESSAGES
(With pulsing sounder). Trouble condition on a Day Zone (zone numbers will scroll).
Press C to silence sounder. Note: Watch Mode must be active.
DAY ZN
ALARM
AC O N
AC O N
Alarm Condition, followed by zone number(s). "ALARM" and zones will display after sys-
tem is disarmed. Note zones, then press C to clear keypad.
(With pulsing sounder). Trouble condition on a FireZone. Press C to silence
sounder. Correct trouble or call for service.
T R O U B L E
AC O N
FireTb
E41-XX
(With pulsing sounder). Alarm condition on a Fire Zone (zone number(s) will scroll).
Press C to silence sounder. Evacuate premises or correct cause of alarm.
r e s e t F I R E AL A R M
AC O N
FIRE
(When Zones Bypassed ("Dsp Bypass") displayed) indicates zone(s) that have been de-
activated, where XX represents the zone number(s).
B Y P A S S E D
AC O N
ZONEXX
(OPTIONAL) (For partitioned systems only). Code not valid for area.
(For Commercial Systems Only). Code not valid for programmed time window.
Wrong code entered or "Easy Bypass" function not enabled.
WRONG/
AREA
AC O N
AC O N
AC O N
WRONG/
TIME
WRONG/
CODE
(OPTIONAL) (In Manager's Mode). Arming prevented due to unsecured zone. "#" represents
CAN'T/ARM/
TROUBLE/AREA #
number of area with unsecured zone. Press area number, then G and D to switch to
that area with faulted zones(s) displayed. The faulted zone can now be secured or bypassed,
and
30
KEYPAD MESSAGES
T R O U B L E
AC O N
Indicates problem(s) detected on the system (see below).
SYSTBL
Check power transformer. Check for blown fuse or circuit breaker; general power outage.
Battery weak. If not recharged within 24 hours, replace battery.
T R O U B L E
AC O N
E01-00/
ACFAIL
T R O U B L E
AC O N
E02-00/
LOBATT
Communication failure to central station.
T R O U B L E
AC O N
E03-00/
COMMFL
(Wireless systems only). Receiver response failure, Receiver No. 1. The following addi-
tional wireless messages may also appear:
T R O U B L E
AC O N
E06-01
“E04-01” - Supervisory trouble on Zone 1 (transmitter has not “checked in”).
“E05-01” - Transmitter on Zone 1 has a low battery;
“E15-01” - Transmitter on Zone 1 has its case open (tamper condition);
(OPTIONAL) (Commercial Systems Only). Overview Mode. Simultaneously shows
status of Areas 1 and 2. “R” Area Ready; “Z” Zone Fault; ‘A” = Area Armed; “B” = Bur-
glary Zone in Alarm; “F” = Fire Zone in Alarm; “T” = Fire Trouble; "c" = Check Trouble;
Area in Function-Display Mode.
OV(RR)
EntNow
AC O N
(Commercial Systems Only). Remote-access keypad unlocked for 5 seconds to allow
entry.
AC O N
31
GLOSSARY
Following are brief descriptions of terms and features used herein that may be unfamiliar to you. Some of the features are
programmable options that may or may not apply to your particular system.
time interval within which closing
(arming) is permitted without
reporting to the central station.
Abort Delay - A delay period that
allows the control panel to be reset,
thus aborting a report to a central
station.
Arming/Disarming - Turning the
system on/off by entering your code
at the keypad, then pressing J.
Communicator - Reports
intrusions, emergencies, openings,
closings, etc. directly to the central
station over telephone lines.
Access Code - A code (up to 6
digits) used to remotely unlock a
door.
Battery - Backup power source in
the control-panel enclosure to
provide protection in the event of a
power failure.
Ambush Code - Either (1) a 2-digit
prefix code entered just prior to the
User Code or (2) a unique 3-6-digit
code used in place of the User Code
when forced to disarm. Sends a
silent alarm to the central station with
no indication at the keypad.
Control Panel - The brain of the
system, it controls all system
functions.
BYPASS Button - Enables you to
manually remove one or more
protective zones from the system.
Directory - (Optional) A listing of
the programmed zone descriptions
stored in memory.
Central Station - Monitors
incoming reports and emergency
messages from a digital
communicator and notifies the proper
authorities.
Easy Arming - Quick arming by
Area - Some systems may be
divided, or partitioned, into smaller
independent subsystems, which are
referred to as Areas. Each Area may
be controlled by its own keypad or by
a keypad of a different Area through
Managers Mode..
pressing J (optional).
Exit/Entry Delays - Separate
delays that let you exit and enter your
premises without setting off an alarm
when the system is armed.
Chime - A keypad beep while
disarmed alerting that the
programmed zone has been opened.
Closing Window - (Optional.) A
32
GLOSSARY
the keypad (G and 7,
8 or 9). If enabled,
pressing G together with 7,
8 or 9 will alert the central
station of a fire, auxiliary, or police
emergency.
of a closing report.
INTERIOR Button - Bypasses
Interior Zones on arming (see Zones -
Interior Zones).
Service Code - A code intended for
temporary use.
Instant Protection - Arming without
entry delay using the F button
while remaining on the premises.
Sounder - A local warning device
at each keypad to alert that (a) entry
delay has started; (b) an attempt was
made to arm with a zone in trouble;
(c) a Day-Zone condition exists (see
Zones: Day Zone); (d) 10 seconds
exit time remaining; (e) invalid code
entered; or (f) central station
Keypad - Puts control-panel
functions at your fingertips. It can be
mounted anywhere in your premises.
Partitioned System - A system that
has been subdivided into two or more
(up to eight) independent subsystems
(areas).
Manager's Mode - In a partitioned
system, a low-security operating
mode that allows arming by area.
Pre-Alarm Warning. - A keypad
sounder alert of an impending alarm.
This option is programmable by zone
for the same duration as that
programmed for Abort Delay (see
Abort Delay).
acknowledged arming (see
Ringback).
Opening Window - (Optional). A
time interval within which opening
(disarming) is permitted without re-
porting to the central station.
System Trouble - A problem (low
battery, power failure, etc.) detected
in the system.
Trouble - A zone fault; an open
door, window, or other problem that
may prevent arming.
Report - A transmission to a central
station notifying of a change in the
status of the system (alarm, trouble,
low battery, etc.).
Overview Mode - In a partitioned
system, a high-security mode of op-
eration allowing area arming wherein
the status of Areas 1 and 2 is simul-
taneously displayed at the keypad.
User Code - Your personalized
code for arming and disarming the
system. It may contain up to six
digits.
Ringback - A beep after arming
verifying the central-station's receipt
Panic Buttons - Blue buttons on
33
GLOSSARY
trouble while disarmed.
Priority Zone: A zone that
prevents arming if in trouble.
Watch Mode - Turns on all Day
Zones simultaneously.
Exit/Entry Follower Zone:
Provides exit and entry delay for
interior devices. Entry delay
only occurs if re-entry takes
place through the normal exit/
entry door first.
Window - A time interval. See
Opening Window; Closing
Window.
Priority Zone with Bypass: A
Priority Zone that can be
bypassed using the
C
Zones - Independent circuits that
protect specific areas of the
premises:
button.
Selective-Bypassed Zone: A
zone that can be individually
Fire Zone: Detects fire alarms
or trouble conditions.
Auto-Bypass Zone: A zone
that will be automatically
bypassed from the protection
system if it is in trouble (faulty)
when the system is armed.
bypassed using the
B
button.
Interior Zones: Circuits within
the premises, usually including
space-protection devices,
interior doors, etc.; but not
exterior doors or windows.
These can all be bypassed
simultaneously using the E
24-Hour Zone: A zone that is
armed and ready at all times to
respond to an emergency
situation.
Burglary Zone:
Detects
intrusion.
Day Zone: A zone, activated by
turning on the Watch Mode, that
will cause a visual and audible
indication at the keypad if it is in
button. (Two groups of Interior
Zones may be programmed for
each area.)
34
SYSTEM TROUBLE ERROR CODES
Your control panel is capable of detecting a variety of troubles that may affect system performance. In the unlikely event that a prob-
lem should occur, one or more of the following error codes may display in the window. Several of these messages are intended for use
by your installer or servicer. If any message appears that is unfamiliar to you, call your security professional for service.
E12-NN Expansion Zone Module Re-
sponse Failure; NN = Module
Number.
E13-NN Expansion Zone Module Tam-
per Condition; NN = Module
Number.
E14-NN Relay Board Response Fail-
ure; NN = Relay Board Num-
ber.
E15-NN RF Transmitter Tamper Condi-
tion; NN = Transmitter Num-
ber.
E20-00 Dealer Program Memory Error.
E21-00 System Shutdown.
E22-NN Sensor Activity Failure; NN =
Zone Number.
E23-00 Burglary Bus Failure.
E24-00 Service Message.
E27-00 Printer Failure
E01-00 AC Power Failure.
E02-00 System Low Battery.
E03-00 Communication Failure.
E04-NN RF Transmitter Supervisory
Failure; NN = Transmitter
Number.
E05-NN RF Transmitter Tow Battery
Condition; NN = Transmitter
Number.
E39-00 Receiver Capacity Error.
E40-00 RF Self-Test Failure
E06-NN Receiver Response Failure;
NN = Receiver Number.
E07-00 Download Failure.
E08-00 Telephone Line Failure
E09-00 System Cold Start.
E41-NN Fire Trouble. NN = Zone Num-
ber
E51-00 Bell Supervisory
E58-00 Telemetry Trouble
E59-00 Telemetry Failure
E66-00 "Clean Me" Smoke Detector
Dirty
E16-NN Receiver Jammed; NN = Re-
ceiver Number.
E17-NN Receiver Tamper Condition;
NN = Receiver Number.
E10-NN Keypad Response Failure;
NN= Keypad Number.
E18-NN Key Fob Transmitter Low Bat-
tery; NN = Key Fob Transmit-
ter Number.
E99-00 Keypad Panic Shorted too
Long
E11-NN Keypad Tamper Condition; NN
= Keypad Number.
E19-00 User Program Memory Error.
35
NAPCO LIMITED WARRANTY
NAPCO SECURITY SYSTEMS, INC. (NAPCO) warrants its products to be free from manufacturing defects assumes, nor authorizes any other person purporting to act on its behalf to modify, to change, or to assume
in materials and workmanship for thirty-six months following the date of manufacture. NAPCO will, within for it, any other warranty or liability concerning its products.
said period, at its option, repair or replace any product failing to operate correctly without charge to the
original purchaser or user.
In no event shall NAPCO be liable for an amount in excess of NAPCO's original selling price of the product,
for any loss or damage, whether direct, indirect, incidental, consequential, or otherwise arising out of any
This warranty shall not apply to any equipment, or any part thereof, which has been repaired by others, failure of the product. Seller's warranty, as hereinabove set forth, shall not be enlarged, diminished or
improperly installed, improperly used, abused, altered, damaged, subjected to acts of God, or on which any affected by and no obligation or liability shall arise or grow out of Seller's rendering of technical advice or
serial numbers have been altered, defaced or removed. Seller will not be responsible for any dismantling or service in connection with Buyer's order of the goods furnished hereunder.
reinstallation charges.
NAPCO RECOMMENDS THAT THE ENTIRE SYSTEM BE COMPLETELY TESTED WEEKLY.
THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, WHICH EXTEND BEYOND THE DESCRIPTION
ON THE FACE HEREOF. THERE IS NO EXPRESS OR IMPLIED WARRANTY OF MERCHANTABILITY Warning: Despite frequent testing, and due to, but not limited to, any or all of the following; criminal
OR A WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. ADDITIONALLY, THIS WARRANTY IS tampering, electrical or communications disruption, it is possible for the system to fail to perform as
IN LIEU OF ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF NAPCO.
expected. NAPCO does not represent that the product/system may not be compromised or circumvented; or
that the product or system will prevent any personal injury or property loss by burglary, robbery, fire or
Any action for breach of warranty, including but not limited to any implied warranty of merchantability, must otherwise; nor that the product or system will in all cases provide adequate warning or protection. A properly
be brought within the six months following the end of the warranty period.
installed and maintained alarm may only reduce risk of burglary, robbery, fire or otherwise but it is not
insurance or a guarantee that these events will not occur. CONSEQUENTLY, SELLER SHALL HAVE NO
IN NO CASE SHALL NAPCO BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE, OR OTHER LOSS BASED ON A
DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, EVEN IF CLAIM THE PRODUCT FAILED TO GIVE WARNING. Therefore, the installer should in turn advise the
THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT.
consumer to take any and all precautions for his or her safety including, but not limited to, fleeing the
premises and calling police or fire department, in order to mitigate the possibilities of harm and/or damage.
In case of defect, contact the security professional who installed and maintains your security system. In
order to exercise the warranty, the product must be returned by the security professional, shipping costs NAPCO is not an insurer of either the property or safety of the user's family or employees, and limits its
prepaid and insured to NAPCO. After repair or replacement, NAPCO assumes the cost of returning products liability for any loss or damage including incidental or consequential damages to NAPCO's original selling
under warranty. NAPCO shall have no obligation under this warranty, or otherwise, if the product has been price of the product regardless of the cause of such loss or damage.
repaired by others, improperly installed, improperly used, abused, altered, damaged, subjected to accident,
nuisance, flood, fire or acts of God, or on which any serial numbers have been altered, defaced or removed. Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or
NAPCO will not be responsible for any dismantling, reassembly or reinstallation charges.
limitation of incidental or consequential damages, or differentiate in their treatment of limitations of liability for
ordinary or gross negligence, so the above limitations or exclusions may not apply to you. This Warranty
This warranty contains the entire warranty. It is the sole warranty and any prior agreements or gives you specific legal rights and you may also have other rights which vary from state to state.
representations, whether oral or written, are either merged herein or are expressly canceled. NAPCO neither
the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
THE FOLLOWING STATEMENT IS REQUIRED BY THE FCC.
following measures: reorient the receiving antenna; relocate the computer with respect to the receiver;
This equipment generates and uses radio-frequency energy and, if not installed and used properly, that
move the computer away from the receiver; plug the computer into a different outlet so that computer and
is, in strict accordance with the manufacturer's instructions, may cause interference to radio and
receiver are on different branch circuits.
television reception. It has been type tested and found to comply with the limits for a Class-B computing
If necessary, the user should consult the dealer or an experienced radio/television technician for
device in accordance with the specifications in Subpart J of Part 15 of FCC Rules, which are designed to
additional suggestions. The user may find the following booklet prepared by the Federal Communications
provide reasonable protection against such interference in a residential installation.
Commission helpful: “How to Identify and Resolve Radio-TV Interference Problems”. This booklet is
available from the U.S. Government Printing Office, Washington, DC 20402; Stock No. 004-000-00345-4.
However, there is no guarantee that interference will not occur in
a
particular installation. If this
equipment does cause interference to radio or television reception, which can be determined by turning
NAPCO Security Systems, 333 Bayview Avenue, Amityville, NY 11701
DESIGN PATS. PENDING
|